Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add filters








Language
Year range
1.
Journal of Xi'an Jiaotong University(Medical Sciences) ; (6): 493-498, 2023.
Article in Chinese | WPRIM | ID: wpr-1005813

ABSTRACT

【Objective】 Digestive tract reconstruction after total gastrectomy is complicated and causes many complications. This study aimed to investigate the feasibility, safety and effectiveness of magnetic compression anastomosis (MCA) for sutureless reconstruction after total gastrectomy in rats. 【Methods】 Twenty-four rats were randomly apportioned to two groups. Reconstruction was performed with MCA in the experimental group or hand-sewn in the control group, and the construction time was recorded. The animals were followed up for 30 days. The survival rate and complications were monitored. At each time point, the rats were euthanized to study the gross/histological morphology and mechanical strength of the anastomoses. 【Results】 The reconstruction time was (12.9±2.7)min in the experimental group and (23.8±4.1)min in the control group (P=0.036). In the experimental group, there was no anastomotic complication. Four control rats developed anastomotic leakage or hemorrhage, and all died within 4 postoperative days. Compared with the control group, burst pressure in the experimental group was similar. Both groups’ anastomoses had smooth gross appearance and histologically good alignment of tissue layers. 【Conclusion】 MCA is a safe and effective choice for reconstruction after total gastrectomy, with better postoperative outcomes than hand-sewn.

2.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 95-99, 2022.
Article in Chinese | WPRIM | ID: wpr-912999

ABSTRACT

@#Objective    To investigate the feasibility of magnamosis rings designed based on magnetic compression technique in esophageal anastomosis reconstruction. Methods    According to the anatomical characteristics of esophagus in SD rats, the esophageal magnamosis rings were designed. SD rats were used as animal models (n=10, 5 males and 5 females) to complete the magnetic anastomosis reconstruction of the cervical esophagus using magnamosis rings, and the operation time, animal survival, postoperative complications, magnetic rings excretion time were recorded. Two weeks after operation, the rats were killed, and the esophageal anastomotic specimens were obtained. The blasting pressure of the anastomotic site was measured and the formation of the anastomotic site was observed with naked eyes. Results    Esophageal magnamosis was successfully performed in 10 SD rats, and the median operation time was 11 (8-13) min. All rats survived without anastomotic leakage, anastomotic stenosis, or magnetic rings incarceration. The magnetic rings were discharged after 8 (5-10) days and the burst pressure was higher than 300 mm Hg. Visual observation showed that the anastomotic muscle healed well and the mucosa was smooth. Conclusion    The magnetic compression technique  can be used for anastomosis reconstruction of esophagus, which has the advantages of simple operation and reliable anastomosis effect, and has clinical application prospect.

3.
Chinese Journal of Medical Instrumentation ; (6): 612-615, 2021.
Article in Chinese | WPRIM | ID: wpr-922070

ABSTRACT

Based on the principle of magnetic anastomosis technique, the design of magnetic anastomosis system for endoscopic tissue clamping is proposed. The system includes a semi-ring magnet, a special structure transparent cap and a detachable push rod. With the help of the existing digestive endoscopy and endoscopic tissue gripper, the endoscopic close clamping and anastomosis of the bleeding or perforated tissue can be completed. After the anastomosis, the magnet falls off and is discharged through the digestive tract. Animal experiments showed that the system was easy to use, the fistula was clamped firmly, the magnet was discharged for 7~21 days, and there was no magnet retention and digestive tract obstruction. Further safety verification, optimization of endoscopic operation, the system can be used in clinical trial.


Subject(s)
Animals , Anastomosis, Surgical , Constriction , Endoscopy, Gastrointestinal , Magnetics , Magnets
4.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 336-342, 2020.
Article in Chinese | WPRIM | ID: wpr-819166

ABSTRACT

@#The earliest research of magnetic surgery was the application of magnetic anastomotic device to anastomose the blood vessels. Now, it has been widely used for anastomosis of blood vessels, gastrointestinal tract and biliary tract. The concept of "magnetic surgery" was named firstly by LU Yi in 2010 and magnetic surgery was classified into magnetic anchoring technique, magnetic navigation technique, magnetic compression technique, magnetic tracing technique, and magnetic suspension technique. The applications of magnetic surgery in the field of thoracic surgery mainly include magnetic compression technique, magnetic anchoring technique and magnetic navigation technique. This paper summarizes the application of magnetic surgery in thoracic surgery and prospects its future development in the field of thoracic surgery.

5.
Chinese Journal of Medical Instrumentation ; (6): 334-336, 2019.
Article in Chinese | WPRIM | ID: wpr-772492

ABSTRACT

Laparoscopic surgery based on magnetic anchor technique has great potential for further minimally invasive surgery and good surgical field exposure, in which the internal grasper is the key factor. In this paper, an internal grasper based on magnetic anchor laparoscopic surgery is designed, which consists of three parts:target magnet, connection module and tissue forceps. The magnetic shield shell is used to wrap the magnetic core in the target magnet, which not only can increase the magnetic force in the working area, but also reduce the magnetic interference between the instruments, and the connecting module can flexibly adjust the length of the internal grasper. The special structure of tissue gripper can effectively reduce deputy injury and facilitate the replacement of clamp position. It has many advantages, such as ingenious design, easy processing, simple operation and wide range of application, which greatly increased its clinical application value.


Subject(s)
Equipment Design , Laparoscopy , Magnetics , Magnets , Surgical Instruments
6.
Organ Transplantation ; (6): 200-204, 2018.
Article in Chinese | WPRIM | ID: wpr-731729

ABSTRACT

Objective To develop a pulling device using magnetic positioning to optimize the procedures of repairment of donor liver from organ donation . Methods The pig liver specimens were used to measure the pull force of repairment of donor liver, magnetic spiderman was developed based on the measurement results. The magnetic spiderman was applied to simulate the repairment of donor liver from organ donation on the pig liver specimens. The effectiveness of magnetic spiderman was also evaluated. Results The pulling force was required all less than 2 N during the repairment of donor liver. The magnetic spiderman was successfully manufactured. The magnets of magnetic spiderman could generate 3 N magnetic forces with paramagnetic basin of hepatic repairment. The self-retraction pull wire of the magnetic spiderman could provide 2.5 N pulling forces. The magnetic spiderman was successfully applied to the simulated experiment of repairment of donor liver from organ donation in 6 cases. The operation time was (54±5) min. No clip slippage,displacement and slippage of the base occurred during the operation. With the cooperation of multiple magnetic spidermen,the remaining surgical procedures were performed by one single surgeon except for the vascular ligation. Conclusions The magnetic spiderman has small volume and implements flexible positioning, can perform pulling operation and nottake up operational space. It can effectively optimize the procedures of repairment of donor liver from organ donation and reduce the quantity of surgeons.

SELECTION OF CITATIONS
SEARCH DETAIL